Error Codes
This page depicts the various Error codes that Axon Server will return in the case of any problems while Processing Client Requests / Message Handling / Administrative Tasks / Cluster Errors.
Last updated
This page depicts the various Error codes that Axon Server will return in the case of any problems while Processing Client Requests / Message Handling / Administrative Tasks / Cluster Errors.
Last updated
Area | Error Code | Description |
---|---|---|
Client Request Processing Errors
AXONIQ-1000
AUTHENTICATION_TOKEN_MISSING
This indicates that the Axon Server has been configured with authentication enabled and a client application did not pass a token.
AXONIQ-1001
AUTHENTICATION_INVALID_TOKEN
This indicates that the Axon Server has been configured with authentication enabled and a client application has supplied an invalid token.
AXONIQ-1002
UNSUPPORTED_INSTRUCTION
This error is returned when the Axon Server cannot recognize the instruction passed to it.
AXONIQ-1003
INSTRUCTION_EXECUTION_ERROR
This error is returned when the Axon Server throws an error during the execution of the instruction passed to it.
AXONIQ-1004
INSTRUCTION_RESULT_TIMEOUT
This indicates that the execution of the instruction did not finish within the timeout set.
AXONIQ-1100
NODE_IS_REPLICA
This error is returned when a request from a node to join a cluster is received by a node that is no longer leader.
Normally the node would forward the request to the leader, but if there is a leader change during the processing of the join request this may happen.
AXONIQ-1300
NO_SUCH_APPLICATION
This error is returned when any client sends any instruction with a specific application name that has not been registered with Axon Server.
AXONIQ-1301
NO_SUCH_NODE
This error is returned when any client sends any instruction with a specific node name that has not been registered with Axon Server.
AXONIQ-1302
CONTEXT_NOT_FOUND
This error is returned when any client sends any instruction with a specific context that has not been registered with Axon Server.
AXONIQ-1304
CONTEXT_EXISTS
This error is returned when there is an instruction to create a specific context within Axon Server and it already exists.
AXONIQ-1400
NO_AXONSERVER_FOR_CONTEXT
This error is returned when there is no Axon Server node available for the specified context.
AXONIQ-1500
AXONSERVER_NODE_NOT_CONNECTED
This error is returned when there is an instruction to create a specific context within Axon Server and it already exists.
Input Errors
AXONIQ-2000
INVALID_SEQUENCE
This error is returned when there is a gap between the sequence number for a particular aggregate instance that the client application sends and the current sequence number for that instance in the Axon Server Event Store.
AXONIQ-2001
PAYLOAD_TOO_LARGE
This error is returned when the payload for the message to be executed is too large.
AXONIQ-2002
TOO_MANY_EVENTS
This error is returned when an ad-hoc query (e.g. from the Search Page) has buffered too many rows to send to the client, this error also is returned when a single transaction from a client contains more than 32767 events (due to a limitation in the event store format, we can only store MAX_SHORT events in a single transaction).
AXONIQ-2100
NO_LEADER_AVAILABLE
This error is returned when no leader is available to execute any instruction sent to the Axon Server cluster.
AXONIQ-2101
NOT_RUNNING_IN_CLUSTER
This error is returned when Axon Server is not running in a cluster.
AXONIQ-2102
CONTEXT_UPDATE_IN_PROGRESS
This error is returned when an instruction on a specific context is rejected as it might be undergoing an update.
AXONIQ-2200
INVALID_TRANSACTION_TOKEN
This error is returned when during replication there is a mismatch between the transaction token in the new transaction and the transaction token that the event store node expects. This means that there is a likely inconsistency in the data between the nodes.
AXONIQ-2301
CLUSTER_NOT_ALLOWED
This error is returned when an instruction to create a cluster is rejected.
AXONIQ-2302
CONTEXT_CREATION_NOT_ALLOWED
This error is returned when an instruction to create a context on an Axon Server cluster is rejected due to invalid permissions.
AXONIQ-2303
NOT_SUPPORTED_IN_DEVELOPMENT
This error is returned when an instruction valid only in non-development mode is attempted when development mode is active.
AXONIQ-2304
CANNOT_DELETE_INTERNAL_CONTEXT
This error is returned when an operation to delete any internal context is attempted on an Axon Server cluster.
AXONIQ-2305
MAX_CLUSTER_SIZE_REACHED
This error is returned when the maximum size of the cluster is reached.
AXONIQ-2306
ALREADY_MEMBER_OF_CLUSTER
This error is returned when an attempt is made to add an already existing node to a cluster.
AXONIQ-2307
NOT_A_MEMBER
This error is returned when a cluster related instruction was sent to a node that is not a member of the cluster.
AXONIQ-2308
INVALID_CONTEXT_NAME
This error is returned when an instruction is attemped on a non-existing context.
AXONIQ-2310
CANNOT_REMOVE_LAST_NODE
This error is returned when a user tries to remove the last node from a replication group. In this case, the user should delete the replication group.
AXONIQ-2311
INVALID_PROPERTY_VALUE
This error is returned in multiple conditions e.g. when creating a context with properties and one of the properties does not have a valid value, also when updating a license and the license file is invalid or the environment variable.
AXONIQ-2500
SAME_NODE_NAME
This error is returned when a node tries to join the cluster with the same internal hostname and port as the leader.
AXONIQ-2501
UNKNOWN_HOST
This error is returned when a hostname was passed that did not resolve to a valid IP address.
AXONIQ-2502
CANNOT_JOIN
This error is returned when a node tries to join the cluster and there is an error.
AXONIQ-2510
UNKNOWN_ROLE
This error is returned when an unknown role is assigned to a user or application. This can only happen when this is done through the REST interface directly or through the CLI.
AXONIQ-2511
INVALID_QUERY
This error is returned when the user sends a query in the search window that is not valid
Rate Limiting Errors
AXONIQ-3000
EVENT_RATE_EXCEEDED
This error is returned when the number of Event messages sent to Axon Server exceeds the processing rate.
Command Handling Errors
AXONIQ-4000
NO_HANDLER_FOR_COMMAND
This error is returned when a command message instruction is sent to the Axon Server and there is no corresponding handler available for it.
AXONIQ-4001
CONNECTION_TO_HANDLER_LOST
This error is returned when Axon Server loses connection to any of the Command Handlers.
AXONIQ-4002
COMMAND_TIMEOUT
This error is returned when a command message instruction is sent to the Axon Server and there is an error while processing it.
AXONIQ-4003
COMMAND_DISPATCH_ERROR
This error is returned when a command message instruction is sent to the Axon Server and there is an error while dispatching it.
Query Handling Errors
AXONIQ-5000
NO_HANDLER_FOR_QUERY
This error is returned when a query message instruction is sent to the Axon Server and there is no corresponding handler available for it.
AXONIQ-5002
QUERY_DISPATCH_ERROR
This error is returned when a query instruction is sent to the Axon Server and there is an error while dispatching it.
Extension Errors
AXONIQ-3004
EVENT_REJECTED_BY_INTERCEPTOR
This error is returned when an interceptor in an extension rejects an event.
AXONIQ-3005
SNAPSHOT_REJECTED_BY_INTERCEPTOR
This error is returned when an interceptor in an extension rejects a snapshot.
AXONIQ-4004
COMMAND_REJECTED_BY_INTERCEPTOR
This error is returned when an interceptor in an extension rejects a command.
AXONIQ-5004
QUERY_REJECTED_BY_INTERCEPTOR
This error is returned when an interceptor in an extension rejects a query.
AXONIQ-5005
SUBSCRIPTION_QUERY_REJECTED_BY_INTERCEPTOR
This error is returned when an interceptor in an extension rejects a subscription query request.
AXONIQ-6100
EXCEPTION_IN_INTERCEPTOR
This error is returned when an interceptor in an extension throws an exception.
Backup Errors
AXONIQ-7000
NODE_NOT_READY_FOR_BACKUP
This error is returned when an Axon Server node is not available for any backup operation.
Internal Errors
AXONIQ-9000
DATAFILE_READ_ERROR
This error is returned when Axon Server is unable to read from the Event/Snapshot Data Files.
AXONIQ-9001
INDEX_READ_ERROR
This error is returned when Axon Server is unable to read from the Index files.
AXONIQ-9100
DATAFILE_WRITE_ERROR
This error is returned when Axon Server is unable to write to the Event/Snapshot Data files.
AXONIQ-9101
INDEX_WRITE_ERROR
This error is returned when Axon Server is unable to write to the Index files.
AXONIQ-9102
DIRECTORY_CREATION_FAILED
This error is returned when Axon Server is unable to create a directory for storing events/snapshots or indexes.
AXONIQ-9200
VALIDATION_FAILED
This error is returned during startup of Axon Server when it performs a validation of the most recent event store segments. This error code is returned when the validation fails.
AXONIQ-9900
TRANSACTION_ROLLED_BACK
This error is returned when any transaction is rolled back.
AXONIQ-9500
INTERRUPTED
This error is returned when Axon Server process is stopped while waiting for events to be written to the event store segment.
AXONIQ-6000
NO_EVENTSTORE
This error is returned when the Axon Server Event Store is not available to perform any instructions.
AXONIQ-6001
CLIENT_DISCONNECTED
This error is returned when an Axon Framework client application disconnects from the Axon Server.
Cluster Errors
AXONIQ-10001
SERVER_TOO_SLOW
This error is returned when any instruction to update the Axon Server cluster fails as the server is too slow to respond.
AXONIQ-10002
UNCOMMITTED_CONFIGURATION
This error is returned when an instruction to update configuration for the Axon Server cluster fails.
AXONIQ-10007
UNCOMMITTED_TERM
This error is returned when a request to update the configuration of a replication group is received before there are any actions committed. The request is refused to prevent potential replication issues.
AXONIQ-10003
REPLICATION_TIMEOUT
This error is returned when the replication process between the nodes of the Axon Server cluster times out.
Other Errors
AXONIQ-0001
OTHER
Any other errors.
AXONIQ-2610
SCHEDULED_EVENT_NOT_FOUND
This error is returned when a scheduled event is not found.